Anest. intenziv. Med. 2012;23(4):188-196

The anaesthetist and new trends and technologies in glucose homeostasisAnaesthesiology - Review articles

Poljaková Iveta1,2
1 Ústav fyziologie Lékařské fakulty Univerzity Palackého v Olomouci
2 Středomoravská nemocniční a. s., Nemocnice Přerov

The review article describes current advances in the control of impaired glucose metabolism in the perioperative and intensive care setting. It includes the use of continuous glucose monitoring systems, the development of closed-loop glycaemic control devices and discusses the measures for perioperative hyperglycaemia reduction.

Keywords: glucose control; continuous glucose monitoring; perioperative care; stress-induced hyperglycaemia; diabetes mellitus; surgery

Received: April 4, 2012; Accepted: June 12, 2012; Published: August 1, 2012  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Poljaková I. The anaesthetist and new trends and technologies in glucose homeostasis. Anest. intenziv. Med. 2012;23(4):188-196.
Download citation

References

  1. Bochicchio, G. V., Joshi, M., Bochicchio, K. M. Early hyperglycemic control is important in critically injured trauma patients. 2007, 63, 6, p. 1353-1359.
  2. Lipshutz, A. K. M., Gropper, M. A., Ramos, M. Perioperative Glycemic Control: An Evidence-based Review. 2009, 110, 2, p. 408-421. Go to original source...
  3. Ramos, M., Khalpey, Z., Lipsitz, S. et al. Relationship of perioperative hyperglycemia and postoperative infections in patients who undergo general and vascular surgery. 2008, 248, 4, p. 585-591. Go to original source...
  4. Poljaková, I., Chlup, R., Kalabus, S. et al. Zkušenosti s perioperativním monitoringem glykémie. 2011, 5, p. 286.
  5. Rice, M. J., Pitkin, A. D., Coursin, D. B. Glucose measurement in the operating room: More complicated than it seems. 2010, 110, p. 1056-1065.
  6. Oliver, N. S.,Toumazou, C., Cass, A. E. G. et al. Glucose sensors: a review of current and emerging technology. 2009, 26, 3, p. 197-210.
  7. Buckingham, B. Clinical overview of continuous glucose monitoring. 2008, 2, 2, p. 300-306.
  8. Kovatchev, B., Anderson, S., Heinemann, L., Clarke, W. Comparison of the Numerical and Clinical Accuracy of Four Continuous Glucose Monitors. 2008, 31, 6, p. 1160-1164. Go to original source...
  9. Chlup, R., Matušková, V., Jadviščoková, T. et al. Prezentováno na 44. diabetologických dnech v Luhačovicích 17.-19. 4. 2008.
  10. Klueh, U., Frayleyi, J., Qiaoi, Y. et al. The role of macrophages in continuous glucose monitoring. 2007, 1, 5, p. 669-675.
  11. Desachy, A., Vuagnat. A. C., Ghazali, A. D. et al. Accuracy of bedside glucometry in critically ill patients: Influence of clinical characteristics and perfusion index. 2008, 83, p. 400-405. Go to original source...
  12. Kanji, S., Buffie, J., Hutton, B. et al. Reliability of point-of-care testing for glucose measurement in critically ill adults. 2005, 33, 12, p. 2778-2785. Go to original source...
  13. Bláha, J. Kontrola glykémie v intenzivní péči. Ne jestli, ale jak. 2009, 19, 3, s. 128-130.
  14. Clarke, W. L., Kovatchev, B. Continuous Glucose Sensors: Continuing Questions about Clinical Accuracy. 2007, 1, 5, p. 669-675.
  15. Kovatchev, B. P., Gonder-Frederick, L. A., Cox, D. J., Clarke, W. L. Evaluating the accuracy of continuous glucose-monitoring sensors: Continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data. 2005, 28, 10, p. 2412-2417. Go to original source...
  16. Clarke, W., Kovatchev, B. Statistical Tools to Analyze Continuous Glucose Monitor Data. Diabetes Technol. Ther., 2009, 11, S1, p. 45-54. Go to original source... Go to PubMed...
  17. Rice, M. J., Coursin, D. B. Continuous Measurement of Glucose: Facts and Challenges. 2012, 116, 1, p. 199-204. Go to original source...
  18. Piper, H. G., Alexander, J. L., Shukla, A. et al. Real-Time Continuous Glucose Monitoring in Pediatric Patients During and After Cardiac Surgery. 2006, 118, 3, p. 1176-1184. Go to original source...
  19. Beauharnais, C. C., Nathan, D. M., Russell, S. J. et al. Presented at Advanced Technologies and Treatments for Diabetes, 5th International Conference, Barcelona, 8.-11. 2. 2012.
  20. Goldberg, P. A., Siegel, M. D., Russell, R. R. et al. Experience with the Continuous Glucose Monitoring System® in a Medical Intensive Care Unit. 2004, 6, 3, p. 339-347. Go to original source...
  21. Rowen, M., Schneider, D. J., Pratley, R. E. et al. On rendering continuous glucose monitoring ready for prime time in the cardiac care unit. 2007, 18, 5, p. 405-409.
  22. Logtenberg, S. J., Kleefstra, N., Snellen, F. et al. Pre- and Postoperative Accuracy and Safety of a Real-Time Continuous Glucose Monitoring System in Cardiac Surgical Patients: A Randomized Pilot Study. 11, 1, 200, p. 31-37.
  23. Allen, H. F., Rake, A., Roy, M. et al. Prospective detection of hyperglycemia in critically ill children using continuous glucose monitoring. 2008, 9, 2, p. 153-158.
  24. Scuffi, C., Lucarelli, F., Valgimigli, F. Presented at Advanced Technologies and Treatments for Diabetes, 5th International Conference, Barcelona, 8.-11. 2. 2012.
  25. Harris, D. L., Battin, B. R., Weston, P.J. et al. Continuous Glucose Monitoring in Newborn Babies at Risk of Hypoglycemia 2010, 157, 2, p.198-202. Go to original source... Go to PubMed...
  26. Platas, I. I., Lluch,M. T., Alminana, N.P. et al. Continuous glucose monitoring in infants of very low birth weight. 2009, 9, p. 217-223.
  27. Stoszková Vlková, A., Dostál, P., Musil, F. et al. Hladina glukózy v krvi a ve tkáni u kriticky nemocných pacientů - srovnání odlišných metod stanovení intersticiální hladiny glukózy. 2009, 3, s. 153-157.
  28. Ligtenberg, J. J., Borggreve, H. F., Sternerdink, A.et al. Subcutaneous glucose measurements and glucose regulation (). 2010, 36, p.897-898. Go to original source...
  29. Brunner, R., Kitzberger, R., Miehsler, W. et al. Accuracy and reliability of asubcutaneous continuous glucose-monitoring system in critically ill patients. 2011, 39, 4, p.659-664. Go to original source...
  30. Holzinger, U., Warszawska, J., Kitzberger, R. et al. Real-time continuous glucose monitoring in critically ill patients: A prospective randomized trial. 2010, 33, p. 467-472. Go to original source...
  31. Holzinger, U., Warszawska, J., Kitzberger, R.et al. Impact of shock requiring norepinephrine on the accuracy and reliability of subcutaneous continuous glucose monitoring. 2009, 35, 8, p.1383-1389. Go to original source...
  32. Bochicchio, G., Joseph, J., Magee,M. Multicenter Evaluation of AFirst Generation Automated Blood Glucose Monitor in the or/Icu. 2011, 39, 12, p.55.
  33. Skjaervold, N. K., Sollgard, E., Hjelme, D. R.et al. Continuous Measurement of Blood Glucose: Validation of aNew Intravascular Sensor. 2011, 114, 1, p.120-125. Go to original source...
  34. Jax, T., Heise,T., Nosek, L. et al. Automated near-continuous glucose monitoring measured in plasma using mid-infrared spectroscopy. 2011, 5, p. 345-352. Go to original source...
  35. Torjman,M. C., Dalal, N., Goldberg, M. E. Glucose Monitoring in Acute Care: Technologies on the Horizon. 2008, 2, 2, p. 178-181. Go to original source...
  36. Joseph, J. I., Hipszer, B., Mraovic, B. et al. Challenges in Glycemic Control in Perioperative and Critically Ill Patients. Clinical Need for Continuous Glucose Monitoring in the Hospital. 2009, 3, 6, p. 1309-1318. Go to original source...
  37. Zhang, K.,Wu, X. Y. Modulated insulin permeation across a glucose-sensitive polymeric composite membrane. 2002, 80, 1-3, p. 169-178. Go to original source...
  38. Hovorka, R. Continuous glucose monitoring and closed-loop systems. 2006, 23, 1, p. 1-12. Go to original source...
  39. Clemens, A.H., Chang, P. H., Myers, R.W. The development of Biostator, aglucose controlled insulin infusion system (GCIIS). 1977, Suppl. 7, p.23-33.
  40. Yatabem, T., Yamazaki, R., Kitagawa, H. et al. The evaluation of the ability of closed-loop glycemic control device to maintain the blood glucose concentration in intensive care unit patients. 2011, 39, p. 575-578. Go to original source...
  41. Cobelli, C., Renard, E., Kovatchev, B. Artificial Pancreas: Past, Present, Future. 2011, 60, 11, p. 2672-2682. Go to original source...
  42. Hanazaki, K., Maeda, H. Tight perioperative glycemic control using an artificial endocrine pankreas. 2010, 40, 1, p. 1-7.
  43. Hanazaki, K., Okabayashi,T. What Should the Targeted Range of Blood Glucose Levels Be to Reduce the Incidence of Surgical Site Infection Following General Surgery? 2011, 146, 3, p.368-369.
  44. Tsukamoto, Z., Okabayashi, T. Progressive artificial endocrine pancreas: The era of novel perioperative blood glucose control for surgery. 2011, 41, 10, p. 1344-1351.
  45. Takahashi,G., Sato, N., Matsumoto, N. et al. Preliminary Study on Glucose Control with an Artificial Pancreas in Postoperative Sepsis Patients. 2011, 47, 1, p. 32-38. Go to original source...
  46. Hanazaki, K., Maeda, H. Relationship between perioperative glycemic control and postoperative infections. 2009, 15, 33, p. 4122-4125.
  47. Chee, F., Fernando,T., van Heerden, P. V. Closed-loop glucose control in critically ill patients using continuous glucose monitoring system (CGMS) in real time. 2003, 7, p. 43-53. Go to original source...
  48. Anderson, R.E., Ehrenberg, J., Barr, G. et al. Effects of thoracic epidural analgesia on glucose homeostasis after cardia surgery in patients with and without diabetes mellitus. 2005, 22, 7, p. 524-529.
  49. Svantfeldt,M., Thorell, A., Nygren, J. et al. Postoperative parenteral nutrition while proactively minimizing insulin resistance. 2006, 22, 5, p.457-464.
  50. Lidder, P., Flanagan, D., Fleming, S., Russell, M. et al. Combining enteral with parenteral nutrition to improve postoperative glucose control. 2010, 103, 11, p. 1635-1641.
  51. Akçay,M. N., Akçay, G. The effects of metformin and oral propranolol on insulin resistance in thermally injured patients. 2005, 17, 2, p. 189-192.
  52. Meier, J. J., Weyhe, D., Michaely,M. et al. Intravenous glucagon-like peptide 1 normalizes blood glucose after major surgery in patients with type 2 diabetes. 2004, 32, 3, p.848-851. Go to original source...
  53. Belhoula, M., Ciébiéra, J. P., De La Chapelle, A.et al. Clonidin premedication improves metabolic control in type 2 diabetic patients during ophthalmic surgery. 2003, 90, 4, p.434-439. Go to original source...
  54. Umpierrez, G., Smiley, D., Zisman, A. et al. Randomized Study of Basal-Bolus Insulin Therapy in the Inpatient Management of Patients With Type 2 Diabetes (RABBIT 2 Trial). 2007, 30, 9, p.2181-2186. Go to original source...




Anesteziologie a intenzivní medicína

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.