Anest. intenziv. Med. 2008;19(3):133-138

Selective bronchial intubation with the UniventR tracheal tube in childrenAnaesthesiology - Original Paper

Mixa Vladimír1,*, Cvachovec Karel1, Rygl Michal2, Šnajdauf Jiří2
1 Klinika anestezie a resuscitace 2. LF UK a FN Motol, Praha
2 Klinika dětské chirurgie 2. LF UK a FN Motol, Praha

Objective:
Selective bronchial intubation is used to isolate and collapse the treated lung. As a rule, intubation is necessary in order to carry out thoracotomies and thoracoscopies. In adults intubation is carried out using a double-lumen tube. In children whose narrow airways do not allow for the insertion of double-lumen tubes, we have been using the Univent endotracheal tube with a movable obturator.

Design:
Clinical, retrospective.
Setting:
Department of Anaesthesia and Intensive Care Medicine, University Hospital.

Materials and methods:
A total of 188 patients aged 1.5 to 18 years were included in the study. The children were grouped according to the size of the Univent tube (Fuji System Corp., Tokyo, Japan) inserted. We noted the diagnoses for which the patients were indicated for surgery, and we assessed the difficulties and complications during the insertion and intraoperative use of the Univent tube.

Results:
There were 4 (2.1%) difficult intubations on induction of anaesthesia; 33 cases (17.5%) of difficult insertion of the obturator; and a failure to introduce the obturator in 9 cases (4.8%). Selective intubation of the lungs was unsuccessful in 14 cases (7.4%). The reasons for these complications are analysed in the text.

Conclusions:
Selective intubation of the lungs with the 100% silicone Univent tube is an easy and gentle method suitable for children aged two and up. It is a fully adequate alternative to the double-lumen tube normally used to secure the airway.

Keywords: paediatric anesthesia; selective intubation; Univent endotracheal tube; biluminal tube; double-lumen tube

Received: February 6, 2008; Accepted: April 2, 2008; Published: June 1, 2008  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Mixa V, Cvachovec K, Rygl M, Šnajdauf J. Selective bronchial intubation with the UniventR tracheal tube in children. Anest. intenziv. Med. 2008;19(3):133-138.
Download citation

References

  1. Mixa, V., Hechtová, D., Blažek, D. Selektivní intubace a ventilace plic v anestezii dětí. Anest. neodkl. Péče, 1999, 10, p. 249-251. Go to original source...
  2. Inoue, H., Shotu, A., Ogawa, J. et al. New device for one lung anesthesia: endotracheal tube with movable blocker. J. Thorac. Cardiovasc. Surg., 1982, 83, p. 940-941. Go to original source... Go to PubMed...
  3. Kayama, H., Krishna, P. R. New endotracheal tube (Univent Tube) for selective blocade of one lung. Anestesiology, 1985, 63, p. 342-343. Go to original source... Go to PubMed...
  4. Inoue, H. Univent endotracheal tube: Twelve-year experience. J. Thorac. Cardiovasc. Surg., 1994, 101, p. 1171-1172. Go to original source...
  5. Gayes, M. J. One-lung ventilation is best accomplished with the Univent endotracheal tube. Journal of Cardiothoracic and Vascular Anesthesia, 1993, 7, p. 103-107. Go to original source... Go to PubMed...
  6. Ransom, E., Detterbeck, F., Klein, J. I., Norfleet, E. A. Univent Tube provides a new technique for jet ventilation. Anestesiology, 1996, 84, p. 724-726. Go to original source... Go to PubMed...
  7. Hammer, G. B., Brodsky, J. B., Redpath, J. et al. The Univent tube for single lung ventilation in children. Paed. Anaesth., 1998, 8, p. 55-57. Go to original source... Go to PubMed...
  8. Hammer, G. B., Fitzmaurice, B. G., Brodsky, J. B. Methods for single-lung ventilation in pediatric patiens. Anesth. Analg., 1999, 89, p. 1426-1429. Go to original source... Go to PubMed...
  9. Wagner, D. L., Gammage, G. W., Wong, M. L. Trachea rupture following the insertion of a disposable double-lumen endotracheal tube. Anestesiology, 1985, 63, p. 698-700. Go to original source... Go to PubMed...
  10. Hasan, A., Low, D. E., Ganado, A. L. et al. Trachea rupture with disposable PVC double-lumen tube. J. Cardiothorac. Vasc. Anesth., 1992, 6, p. 208-211. Go to original source... Go to PubMed...
  11. Hammer, G. B., Manos, S. J., Smith, B. M. et al. Single lung ventilation in pediatric patiens. Anestesiology, 1996, 84, p. 1503-1506. Go to original source... Go to PubMed...
  12. Gayes, M. J. Management of Univent bronchial blocking ballon perforation: one-lung ventilation. Anesth. Analg., 1994, 79, p. 1210. Go to original source... Go to PubMed...
  13. Brodsky, J. B., Macario, A., Mark, J. B. D. Tracheal diameter predicts double-lumen tube size: a method for selecting left double lumen tubes. Anesth. Analg., 1996, 82, p. 861-864. Go to original source... Go to PubMed...
  14. Fitzmaurice, B. G., Brodsky, J. B. Airway rupture from double-lumen tubes. J. Cardiothorac. Vasc. Anesth, 1999, 13, p. 322-329. Go to original source... Go to PubMed...
  15. Hanallah, M. S., Benumof, J. L. Comparison of two techniques to inflate the bronchial cuff of the Univent tube. Anesth. Analg., 1992, 75, p. 784-787. Go to original source... Go to PubMed...
  16. Karwadale, S. V. A new tube for single lung ventilation. Chest, 1987, 92, p. 761-763. Go to original source... Go to PubMed...
  17. Hanallah, M. S. The Univent tube: Bronchial cuff inflation. Anestesiology, 1991, 75, p. 165-166. Go to original source... Go to PubMed...
  18. Benumof, J. L. Separation of the two lungs. In Benumof, J. L. Anaesthesia for thoracic surgery. 2nd edition, WB Saunders comp. : Philadelphia 1995, p. 370-379.
  19. Fuji System Corp: Univent (promotional brochure). Fuji System Corp, 23-14 Hong 3 Chrome, Bunkyo-Ku, Tokyo, 113 Japan.
  20. Ransom, E., Detterbeck, F., Klein, J. I., Norfleet, E. A. Univent tube provides a new technique for jet ventilation. Anestesiology, 1996, 84, 3, p. 724-726. Go to original source... Go to PubMed...
  21. Williams, H., Gothard, J. Jet ventilation via a Univent tube for sleeve pneumectomy. Eur. J. Anaesthesiol., 2001, 18, p. 407-409. Go to original source... Go to PubMed...




Anesteziologie a intenzivní medicína

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.