Anest. intenziv. Med. 2006;17(4):220-223

New developments in haemodynamic monitoring: Part IIIntensive Care Medicine - Comprehensive Report

P. Suk, V. ©rámek
Anesteziologicko-resuscitační klinika, FN u svaté Anny v Brně

This review article summarizes new trends in systemic haemodynamic monitoring in 2005. This part is aimed at the less invasive cardiac output measurement methods, particularly transoesophageal Doppler and venous oximetry, and the application of protocols for optimization of the haemodynamics and oxygen delivery.

Keywords: haemodynamic monitoring; cardiac output; transoesophageal Doppler; venous oximetry

Published: August 1, 2006  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Suk P, ©rámek V. New developments in haemodynamic monitoring: Part II. Anest. intenziv. Med. 2006;17(4):220-223.
Download citation

References

  1. Dark, P. M., Singer, M. The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults. Intensive Care Med., 2004, 30, p. 2060-2066. Go to original source... Go to PubMed...
  2. Sawai, T., Nohmi, T., Ohnishi, Y., Takauchi, Y., Kuro, M. Cardiac Output Measurement Using the Transesophageal Doppler Method Is Less Accurate Than the Thermodilution Method When Changing PaCO2. Anesth. Analg., 2005, 101, p. 1597-1601. Go to original source... Go to PubMed...
  3. Slama, M., Masson, H., Teboul, J. L., Arnould, M. L., Nait-Kaoudjt, R., Colas et al. Monitoring of respiratory variations of aortic blood flow velocity using esophageal Doppler. Intensive Care Med., 2004, 30, 6, p. 1182-1187. Go to original source... Go to PubMed...
  4. Monnet, X., Rienzo, M., Osman, D., Anguel, N., Richard, C., Pinsky, M. R. et al. Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients. Intensive Care Med., 2005, 31, 9, p. 1195-1201. Go to original source... Go to PubMed...
  5. Valle, F., Fourcade, O., De Soyres, O., Angles, O., Sanchez-Verlaan, P., Pillard, F. Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response. Intensive Care Med., 2005, 31, p. 1388-1393. Go to original source... Go to PubMed...
  6. de Vaal, J. B., de Wilde, R. B., van den Berg, P. C., Scgreuder, J. J., Jansen, J. R. Less invasive determination of cardiac output from the arterial pressure by aortic diameter-callibrated pulse contour. Br. J. Anaeth., 2005, 95, 3, p. 326-331. Go to original source... Go to PubMed...
  7. Brown, C. V., Martin, M. J., Shoemaker, W. C., Wo, C. C., Chan, L., Azarow, K. et al. The effect of obesity on bioimpedance cardiac index. Am. J. Surg., 2005, 189, 5, p. 547-550. Go to original source... Go to PubMed...
  8. Schmidt, C., Theilmeier, G., Van Aken, H., Korsmeier, P., Wirtz, S. P., Berendes, E. et al. Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output. Br. J. Anaesth., 2005, 95, 5, p. 603-610. Go to original source... Go to PubMed...
  9. Gabbanelli, V., Pantanetti, S., Donati, A., Montozzi, A., Carbini, C., Pelaia, P. Initial distribution volume of glucose as noninvasive indicator of cardiac preload: comparison with intrathoracic blood volume. Intensive Care Med., 2004, 30, 11, p. 2067-2073. Go to original source... Go to PubMed...
  10. Maarek, J. M., Holschneider, D. P., Harimoto, J., Yang, J., Scremin, O. U., Rubinstein, E. H. Measurement of Cardiac Output with Indocyanine Green Transcutaneous Fluorescence Dilution Technique. Anesthesiology, 2004, 100, p. 1476-1483. Go to original source... Go to PubMed...
  11. Taguchi, N., Nakagawa, S., Miyasaka, K., Fuse, M., Aoyagi, T. Cardiac output measurement by pulse dye densitometry using three wavelengths. Pediatr. Crit. Care Med., 2004, 5, p. 343-350. Go to original source... Go to PubMed...
  12. Baulig, W., Bernhard, E. O., Bettex, D., Schmidlin, D., Schmid, E.R. Cardiac output measurement by pulse dye densitometry in cardiac surgery. Anaesthesia, 2005, 60, 10, p. 968-973. Go to original source... Go to PubMed...
  13. Reinhart, K., Kuhn, H. J., Hartog, C. et al. Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill. Intensive Care Med., 2004, 30, p. 1572-1578. Go to original source... Go to PubMed...
  14. Chawla, L. S., Zia, H., Gutierrez, G., Katz, N. M., Seneff, M. G., Shah, M. Lack of Equivalence Between Central and Mixed Venous Oxygen Saturation. Chest, 2004, 126, p. 1891-1896. Go to original source... Go to PubMed...
  15. Bendjelid, K., Schutz, N., Suter, P. M., Romand, J. A. Continuous SvO2 measurements and co-oximetry are not interchangeable immediately after cardiopulmonary bypass. Can. J. Anaesth., 2004, 51, 6, p. 610-615. Go to original source... Go to PubMed...
  16. Dueck, M. H., Klimek, M., Appenrodt, S., Weigand, C., Boerner, U. Trends but Not Individual Values of Central Venous Oxygen Saturation Agree with Mixed Venous Oxygen Saturation during Varying Hemodynamic Conditions. Anesthesiology, 2005, 103, p. 249-257. Go to original source... Go to PubMed...
  17. Wei Wei, Zhaoqiong Zhu, Lunxu Liu, Yunxia Zuo et al. A Pilot Study of Continuous Transtracheal Mixed Venous Oxygen Saturation Monitoring. Anesth. Analg., 2005, 101, p. 440-443. Go to original source... Go to PubMed...
  18. Wang, X. R., Zheng, Y. J., Tian, J., Wang, Z. H., Pan, Z. Y. A preliminary study on the monitoring of mixed venous oxygen saturation through the left main bronchus. Crit. Care, 2005, 10, 1, R7 [Epub před tiskem]. Go to original source... Go to PubMed...
  19. Pearse, R., Dawson, D., Fawcett, J., Rhodes, A., Grounds, R. M., Bennett, E. D. Changes in central venous saturation after major surgery, and association with outcome. Critical Care, 2005, 9, p. 694-699. Go to original source... Go to PubMed...
  20. Divatia, J., Priya, V., Shingade, R. Impact of low postoperative central venous oxygen saturation on postoperative morbidity. Critical Care, 2005, 9, Suppl. 1, p. 46. Go to original source...
  21. Matos Nogueira, P., Viera Gomes, R., Rouge, A., Fernandes, M., Tura, B., Rocco, J. et al. Can central venous oxygen saturation intermitently measured within the fisrt 24 postoperative hours of cardiac surgery predict death? Critical Care, 2005, 9, Suppl. 1, p. 47. Go to original source...
  22. Pearse, R., Dawson, D., Fawcett, J., Rhodes, A., Grounds, R. M., Bennett, E. D. Early goal-directed therapy after major surgery reduces complications and duration of hospital stay. A randomised, controlled trial. Critical Care, 2005, 9, p. 687-693. Go to original source... Go to PubMed...
  23. Wakeling, H. G., McFall, M. R., Jenkins, C. S., Woods, W. G., Miles, W. F., Barclay, G. R., Fleming, S. C. Intraoperative oesophageal Doppler guided fluid management shortens postoperative hospital stay after major bowel surgery. Br. J. Anaesth., 2005, 95, p. 634-642. Go to original source... Go to PubMed...
  24. McKendry, M., McGloin, H., Saberi, D., Caudwell, L., Brady, A. R., Singer, M. Randomised controlled trial assessing the impact of a nurse delivered, flow monitored protocol for optimisation of circulatory status after cardiac surgery. BMJ, 2004, 329, p. 258-262. Go to original source... Go to PubMed...
  25. Poeze, M., Solberg, B. C., Greve, J. W., Ramsay, G. Monitoring global volume-related hemodynamic or regional variables after initial resuscitation: What is a better predictor of outcome in critically ill septic patients? Crit. Care Med., 2005, 33, 11, p. 2494-2500. Go to original source... Go to PubMed...
  26. Miami Trauma Clinical Trials Group Splanchnic hypoperfusion-directed therapies in trauma: a prospective, randomized trial. Am. Surg., 2005, 71, 3, p. 252-260. Go to PubMed...




Anesteziologie a intenzivní medicína

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.