Anest. intenziv. Med. 2004;15(2):69-73

The Relation between Skeletal Muscle Blood Flow and Selected Parameters of Metabolism during Cardiac Surgery with Cardiopulmonary BypassArticles

P. Živný1, J. Manďák2, V. Palička1, P. Hrubá1, V. Lonský2, P. Kuneš2, J. Kubíček2
1 Ústav klinické biochemie a diagnostiky Univerzity Karlovy v Praze, Fakulty lékařské a Fakultní nemocnice v Hradci Králové, přednosta prof. MUDr. V. Palička, CSc. 2Kardiochirurgická klinika Univerzity Karlovy v Praze, Fakulty lékařské a Fakultní nemocnice

Objective:
The aim of the study was to compare the interstitial metabolism of glucose, lactate, urea and glycerol in skeletalmuscle with interstitial blood flow by microdialysis in two groups of patients undergoing cardiac surgery with a cardiopulmonarybypass (CBP) under normothermic and hypothermic conditions.

Design: Prospective randomised study.Setting: Institute of Clinical Biochemistry and Diagnostics, Department of Cardiosurgery, University Hospital, Hradec Králové.

Material and Methods: Microdialysis was performed in forty patients undergoing cardiac surgery with a cardiopulmonarybypass (CBP). After an institutional approval, patients were randomized into two groups. Group 1 (NT, N=20): patients wereoperated under normothermic condition (36 °C). Group 2 (HT, N=20): patients were operated under hypothermic conditions(32 °C). Two microdialysis (MD) probes CMA 60 (CMA Microdialysis AB) were inserted into a standard site of musculusdeltoideus during introduction of anaesthesia. Microdialysis was performed with Ringer's solution with perfusion flow 0.3ml/hour (300 µl/hour). Microdialysis samples were collected: 0) initial phase of operation, 1) beginning of operation tobeginning of CPB, 2) CPB 3) end of CPB to the end of operation, 4) 2 hours, 5) 4 hours, 6) 6 hours and 7) 8 hours after surgery.Microdialysate glucose, urea and lactate levels (mmol/l) were assessed by Hitachi 917 analyser, glycerol concentration bykit (Randox). Interstitial blood flow was monitored using flow marker gentamicin added in a known concentration inmicrodialysis fluid. Microdialysis gentamicin concentration was estimated by Axsym analyser (Abbott) - FPIA Method.

Results: Glucose concentration in a skeletal muscle microdialysate during the 1st to the 4th intervals was higher in NTpatients comparing to HT patients, and than lower. The similar applied for urea concentration. There were no significantdifferences in concentration of lactate and glycerol between groups. Gentamicin microdialysate concentrations weresignificantly higher in HT patients in comparison with NT patients at all intervals.

Conclusion: We suppose that interstitial concentrations of analytes during CPBwere influenced both by blood flow changesand by metabolic changes in skeletal muscle cells. Suppression of glucose synthesis after CPB was described by otherauthors. There were other factors influencing interstitial metabolism, for instance dramatic changes in capillary fluid pressure and osmolality.

Keywords: microdialysis; flow marker; skeletal muscle; extracorporeal circulation

Published: April 1, 2004  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Živný P, Manďák J, Palička V, Hrubá P, Lonský V, Kuneš P, Kubíček J. The Relation between Skeletal Muscle Blood Flow and Selected Parameters of Metabolism during Cardiac Surgery with Cardiopulmonary Bypass. Anest. intenziv. Med. 2004;15(2):69-73.
Download citation




Anesteziologie a intenzivní medicína

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.