Anest. intenziv. Med. 2002;13(3):124-126

Influence of All-in-one System on Biological Insulin AvailabilityArticles

Z. Rušavý, R. Suchá, E. Langhamerová, V. Šrámek, S. Lacigová, P. Tešínský
I. interní klinika UK, LF a FN, Plzen, prednosta prof. MUDr. Karel Opatrný, CSc.

In clinical practice, it is necessary to reduce the daily dose of insulin added to all-in-one system in comparison with the daily dose administered bya linear dosing device (perfusor) in physiological solution. The aim of the study is to asses the influence of the base solution on biological insulinavailability expressed in the value of total insulin using the RIA method, and to monitor the influence of the base solution on total insulin concentrationin time.

Methods: 15 measurements of total insulin concentration in physiological solution applied by a linear dosing device (8j Actrapid HM + 20 mlphysiological solution) were carried out in time intervals of 1, 5, 10, 30, 60, 90 and 210 minutes and 15 measurements in mixture of all-in-one nutrition(8j Actrapid + 20 ml all-in-one solution) were carried out in the same way. Total insulin was measured using the RIA method. For statistical evaluation,the MANOVA, ANOVA and paired T-test with Bonferroni correction were used.

Results: Average values of insulin concentration in physiological solution were in the given time intervals 21.5 ± 11.3 IU/l (5.4 %of the theoreticallycalculated concentration). When separate time points for saline were analysed major changes were seen at the very beginning of the experiment (adecrease from 26 ± 8.47 at baseline to 20 ± 7.57 at 5 minutes; P < 0.001). Significant changes were also measured between 30 and 60 minutes (21 ±9.60 vs. 26 ± 11.00); P < 0.05) and 60 and 90 minutes (26 ± 11.00 vs. 25 ± 6.94; P = 0.01) showing a stepwise IRI concentration increase. The levelof insulin in all-in-one solution did not change in time and it reached the values of 115.2 ± 22.3 (28.8 % of the theoretically calculated concentration).

Conclusion: The availability of insulin applied by a linear dosing device is significantly higher in all-in-one solution than in physiological solution,furthermore the insulin stability in time is higher. The difference is most probably caused by smaller insulin absorption to syringe walls and to the set,owing to the amino-acids in the mixture.

Keywords: linear dosing device; insulin; stability of insulin; physiological solution

Published: June 1, 2002  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Rušavý Z, Suchá R, Langhamerová E, Šrámek V, Lacigová S, Tešínský P. Influence of All-in-one System on Biological Insulin Availability. Anest. intenziv. Med. 2002;13(3):124-126.
Download citation




Anesteziologie a intenzivní medicína

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.