Anest. intenziv. Med. 2014;25(3):222-230
Current techniques of continuous non-invasive monitoring of arterial blood pressureIntesive Care Medicine - Review Article
- Anesteziologicko-resuscitační klinika, Fakultní nemocnice Plzeň
Blood pressure is one of the most important parameters monitored in anaesthesia and intensive care medicine. Two possibilities of automatic blood pressure monitoring are at hand in contemporary practice: intermittent measurements obtained via an oscillometric cuff or continuous monitoring based on arterial catheterisation. In recent years novel technologies have been developed enabling continuous non-invasive monitoring of blood pressure. This review article describes the two most developed of these technologies: the volume clamp method and appalanation tonometry. Devices based on these principles might in near future help to significantly improve patients' safety and quality of care.
Keywords: blood pressure monitoring; non-invasive technologies; volume clamp; applanation tonometry
Received: September 16, 2013; Accepted: December 1, 2013; Published: June 1, 2014 Show citation
References
- ASA House of Delegates STANDARDS FOR BASIC ANESTHETIC MONITORING. [online] 2011 [cit.2013-07-12]. Dostupný na www: http://www.asahq.org/For-Members/~/media/For%20Members/documents/Standards%20Guidelines%20Stmts/Basic%20Anesthetic%20Monitoring%202011.ashx.
- Cvachovec, K., Černý, V., Herold, I., Kozlík, P., Šturma, J. Zásady bezpečné anesteziologické péče. [online] 2012 [cit.2013-07-12]. Dostupný na www: http://www.csarim.cz/Public/csim/22%20%20DP_safety_anesth_CSARIM_final_approval_140212.pdf.
- Sy, W. P. Ulnar nerve palsy possibly related to use of automatically cycled blood pressure cuff. Anesth. Analg., 1981, 60, p. 687-688.
Go to original source...
- Bause, G. S., Weintraub, A. C., Tanner, G. E. Skin avulsion during oscillometry. J. Clin. Monit., 1986, 2, p. 262-263.
Go to original source...
Go to PubMed...
- Cannesson, M., Pestel, G., Ricks, C., Hoeft, A., Perel, A. Hemodynamic monitoring and management in patients undergoing high risk surgery: a survey among North American and European anesthesiologists. Crit. Care, 2011, 15, R197.
Go to original source...
Go to PubMed...
- Scheer, B., Perel, A., Pfeiffer, U. J. Clinical review: complica-tions and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit. Care, 2002, 6, p. 199-204.
Go to original source...
Go to PubMed...
- Lamia, B., Chemla, D., Richard, C., Teboul, J. L. Clinical review: interpretation of arterial pressure wave in shock states. Crit. Care, 2005, 9, p. 601-606.
Go to original source...
Go to PubMed...
- Montenij, L. J., de Waal, E. E. C., Buhre, W. F. Arterial waveform analysis in anesthesia and critical care. Curr. Opin. Anaesthesiol., 2011, 24, p. 551-556.
Go to original source...
Go to PubMed...
- O'Brien, E. et al. Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults. Blood Press Monit, 2002, 7, p. 3-17.
Go to original source...
Go to PubMed...
- Pickering, T. G. et al. Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Hypertension, 2005, 45, p. 142-161.
Go to original source...
Go to PubMed...
- Marey, E. Pression et vitesse du sang. Physiologie Expe-rimentale, 1876.
- Drzewiecki, G., Hood, R., Apple, H. Theory of the oscillometric maximum and the systolic and diastolic detection ratios. Ann. Biomed. Eng., 1994, 22, p. 88-96.
Go to original source...
Go to PubMed...
- Smulyan, H., Safar, M. E. Blood pressure measurement: retrospective and prospective views. American Journal of Hypertension, 2011, 24, p. 628-634.
Go to original source...
Go to PubMed...
- Marks, L. A., Groch, A. Optimizing cuff width for noninvasive measurement of blood pressure. Blood Press Monit., 2000, 5, p. 153-158.
Go to original source...
Go to PubMed...
- Avolio, A. P., Butlin, M., Walsh, A. Arterial blood pressure measurement and pulse wave analysis-their role in enhancing cardiovascular assessment. Physiol. Meas., 2010, 31, R1-47.
Go to original source...
Go to PubMed...
- Penaz, J. Photoelectric measurement of blood pressure, volume and flow in the finger. In Digest of the 10th International Conference on Medical and Biological Engineering, Dresden
- Wesseling, K. A century of noninvasive arterial pressure measurement: from Marey to Penaz and Finapres. Homeostasis., 1995, p. 2-3.
- Ilies, C. et al. Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement. Br. J. Anaesth., 2012, 108, p. 202-210.
Go to original source...
Go to PubMed...
- Wesseling, K. H., de Wit, B., van der Hoeven, G. M. A., van Goudoever, J., Settels, J. Physiocal, calibrating finger vascular physiology for Finapres. Homeostasis, 1995, 36, p. 67-82.
- Gizdulich, P., Prentza, A., Wesseling, K. H. Models of brachial to finger pulse wave distortion and pressure decrement. Cardiovasc. Res., 1997, 33, p. 698-705.
Go to original source...
Go to PubMed...
- Fischer, M. O. et al. Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery. Br. J. Anaesth., 2012, 109, p. 514-521.
Go to original source...
Go to PubMed...
- Martina, J. R. et al. Noninvasive continuous arterial bloodpressure monitoring with Nexfin®. Anesthesiology, 2012, 116, p. 1092-1103.
Go to original source...
Go to PubMed...
- Garnier, R. P., van der Spoel, A. G. E., Sibarani-Ponsen, R., Markhorst, D. G., Boer, C. Level of agreement between Nexfin non-invasive arterial pressure with invasive arterial pressure measurements in children. Br. J. Anaesth., 2012, 109, p. 609-615.
Go to original source...
Go to PubMed...
- Lemson, J. et al. The reliability of continuous noninvasive finger blood pressure measurement in critically ill children. Anesth. Analg., 2009, 108, p. 814-821.
Go to original source...
Go to PubMed...
- Hofhuizen, C. M. et al. Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery. Br. J. Anaesth., 2012, 105, p. 493-500.
Go to original source...
Go to PubMed...
- Stover, J. F. et al. Noninvasive cardiac output and bloodpressure monitoring cannot replace an invasive monitoring system in critically ill patients. BMC Anesthesiology, 2009, 9, 6.
Go to original source...
Go to PubMed...
- Hohn, A. et al. Non-invasive continuous arterial pressure monitoring with Nexfin(R) does not sufficiently replace invasive measurements in critically ill patients. Br. J. Anaesth., 2013, 111, p. 178-184.
Go to original source...
Go to PubMed...
- Akkermans, J. et al. Continuous Non-Invasive Blood Pressure Monitoring, a Validation Study of Nexfin in a Pregnant Population. Hypertension in Pregnancy, 2009, 28, p. 230-242.
Go to original source...
Go to PubMed...
- Nowak, R. M. et al. Noninvasive continuous or intermittent blood pressure and heart rate patient monitoring in the ED. Am. J. Emerg. Med., 2011, 29, p. 782-789.
Go to original source...
Go to PubMed...
- Eeftinck Schattenkerk, D. W. et al. Nexfin noninvasive continuous blood pressure validated against Riva-Rocci/Korotkoff. American journal of hypertension, 2009, 22, p. 378-383.
Go to original source...
Go to PubMed...
- ANSI/AAMI American National Standard for Manual, Electronic, or Automated Sphygmomanometers. In, Arlington, VA.
- Bur, A. et al. Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients. Crit. Care Med., 2000, 28, p. 371-376.
Go to original source...
Go to PubMed...
- Wesseling, K. H., Jansen, J. R., Settels, J. J., Schreuder, J. J.Computation of aortic flow from pressure in humans using a nonlinear, three-element model. J. Appl. Physiol., 1993, 74, p. 2566-2573.
Go to original source...
Go to PubMed...
- Truijen, J., van Lieshout, J. J., Wesselink, W. A., Wester-hof, B. E. Noninvasive continuous hemodynamic monitoring.J. Clin. Monit. Comput., 2012, 26, p. 267-278.
Go to original source...
Go to PubMed...
- Fischer, M. O. et al. Assessment of changes in cardiac index and fluid responsiveness: a comparison of Nexfin and transpulmonary thermodilution. Acta Anaesthesiol. Scand., 2013, 57, p. 704-712.
Go to original source...
Go to PubMed...
- Monnet, X. et al. The estimation of cardiac output by the Nexfin device is of poor reliability for tracking the effects of a fluid challenge. Crit. Care, 2012, 16, R212.
Go to original source...
Go to PubMed...
- Broch, O. et al. A comparison of the Nexfin® and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery. Anaesthesia, 2012, 67, p. 377-383.
Go to original source...
Go to PubMed...
- Trinkmann, F. et al. Is arterial pulse contour analysis using Nexfin a new option in the noninvasive measurement of cardiac output? A pilot study. J. Cardiothorac. Vasc. Anesth., 2013, 27, p. 283-287.
Go to original source...
Go to PubMed...
- van der Spoel, A. G. E., Voogel, A. J., Folkers, A., Boer, C., Bouwman, R. A. Comparison of noninvasive continuous arterial waveform analysis (Nexfin) with transthoracic Doppler echocardiography for monitoring of cardiac output. J. Clin. Anesth., 2012, 24, p. 304-309.
Go to original source...
Go to PubMed...
- Chen, G. et al. Comparison of noninvasive cardiac output measurements using the Nexfin monitoring device and the esophageal Doppler. J. Clin. Anesth., 2012, 24, p. 275-283.
Go to original source...
Go to PubMed...
- Bogert, L. W. J. et al. Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease. Anaesthesia, 2010, 65, p. 1119-1125.
Go to original source...
Go to PubMed...
- Critchley, L. A., Critchley, J. A. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J. Clin. Monit. Comput., 1999, 15, p. 85-91.
Go to original source...
Go to PubMed...
- Lansdorp, B. et al. Non-invasive measurement of pulsepressure variation and systolic pressure variation using a finger cuff corresponds with intra-arterial measurement. Br. J. Anaesth., 2011, 107, p. 540-545.
Go to original source...
Go to PubMed...
- Fortin, J. et al. Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops. Comput. Biol. Med., 2006, 36, p. 941-957.
Go to original source...
Go to PubMed...
- Biais, M. et al. Continuous non-invasive arterial pressure measurement: evaluation of CNAP device during vascular surgery. Ann. Fr. Anesth. Reanim., 2010, 29, p. 530-535.
Go to original source...
Go to PubMed...
- Jeleazcov, C. et al. Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesia. Br. J. Anaesth., 2010, 105, p. 264-272.
Go to original source...
Go to PubMed...
- Gayat, E. et al. CNAP(reg) does not reliably detect minimal or maximal arterial blood pressures during induction of anaesthesia and tracheal intubation. Acta Anaesthesiol. Scand., 2013, 57, p. 468-473.
Go to original source...
Go to PubMed...
- Hahn, R., Rinösl, H., Neuner, M., Kettner, S. C. Clinical validation of a continuous non-invasive haemodynamic monitor (CNAP 500) during general anaesthesia. Br. J. Anaesth., 2012, 108, p. 581-585.
Go to original source...
Go to PubMed...
- Biais, M. et al. The ability of pulse pressure variations obtained with CNAP™ device to predict fluid responsiveness in the operating room. Anesth. Analg., 2011, 113, p. 523-528.
Go to original source...
Go to PubMed...
- Monnet, X. et al. Prediction of fluid responsiveness by a continuous non-invasive assessment of arterial pressure in critically ill patients: comparison with four other dynamic indices. Br. J. Anaesth., 2012, 109, p. 330-338.
Go to original source...
Go to PubMed...
- Ilies, C. et al. Detection of hypotension during Caesarean section with continuous non-invasive arterial pressure device or intermittent oscillometric arterial pressure measurement. Br. J. Anaesth., 2012, 109, p. 413-419.
Go to original source...
Go to PubMed...
- Jagadeesh, A. M., Singh, N. G., Mahankali, S. A comparison of a continuous noninvasive arterial pressure (CNAP&trade) monitor with an invasive arterial blood pressure monitor in the cardiac surgical ICU. Ann. Card. Anaesth., 2012, 15, p. 180-184.
Go to original source...
Go to PubMed...
- Kako, H., Corridore, M., Rice, J., Tobias, J. D. Accuracy of the CNAP™ monitor, a noninvasive continuous blood pressure device, in providing beat-to-beat blood pressure readings in pediatric patients weighing 20-40 kilograms. Paediatr. Anaesth., 2013.
Go to original source...
- Dueck, R., Goedje, O., Clopton, P. Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry. J. Clin. Monit. Comput., 2012, 26, p. 75-83.
Go to original source...
Go to PubMed...
- Saugel, B. et al. The T-Line TL-200 system for continuous non-invasive blood pressure measurement in medical intensive care unit patients. Intensive Care Med., 2012, 38, p. 1471-1477.
Go to original source...
Go to PubMed...
- Szmuk, P., Pivalizza, E., Warters, R. D., Ezri, T., Gebhard, R. An evaluation of the T-Line Tensymeter continuous noninvasive blood pressure device during induced hypotension. Anaesthesia, 2008, 63, p. 307-312.
Go to original source...
Go to PubMed...
- Janelle, G. M., Gravenstein, N. An accuracy evaluation of the T-Line Tensymeter (continuous noninvasive blood pressure mana-gement device) versus conventional invasive radial artery monitoring in surgical patients. Anesth. Analg., 2006, 102, p. 484-490.
Go to original source...
Go to PubMed...
- Meidert, A. S. et al. Evaluation of the radial artery applanation tonometry technology for continuous noninvasive blood pressure monitoring compared with central aortic blood pressure measurements in patients with multiple organ dysfunction syndrome.J. Crit. Care, 2013.
Go to original source...
Go to PubMed...
- Chen, W., Kobayashi, T., Ichikawa, S., Takeuchi, Y., Toga-wa, T. Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration. Med. Biol. Eng. Comput., 2000, 38, p. 569-574.
Go to original source...
Go to PubMed...
- Ahlstrom, C., Johansson, A., Uhlin, F., Länne, T., Ask, P. Noninvasive investigation of blood pressure changes using the pulse wave transit time: a novel approach in the monitoring of hemodialysis patients. J. Artif. Organs., 2005, 8, p. 192-197.
Go to original source...
Go to PubMed...
- Ishihara, H. et al. The ability of a new continuous cardiac output monitor to measure trends in cardiac output following implementation of a patient information calibration and an automated exclusion algorithm. J. Clin. Monit. Comput., 2012, 26, p. 465-471.
Go to original source...
Go to PubMed...