Anest. intenziv. Med. 2009;20(3):149-152
Catheter-related blood stream infectionsIntensive Care Medicine - Original Paper
- Klinika anesteziologie a resuscitace UK 2. LF a IPVZ, Fakultní nemocnice v Motole, Praha
Objective:
To evaluate the occurrence of catheter related blood stream infections in the critical care department when using antimicrobial coated central venous catheters.
Design:
Cross-sectional study.
Setting:
Critical care unit, Department of Anaesthesiology and Intensive Care Medicine University Hospital.
Material and method:
During the period 1. 4. 2007-31. 12. 2007 we monitored number of inserted catheters, duration of insertion and bacterial colonisation from the catheter tips and hemocultures.
Results:
Overall number of inserted catheters was 270, mean insertion time was 7.5 days, 16 catheters (5.9%) were colonised, match with the hemocultures in 1 case (0.4%). This corresponds to 0.5/1000 catheter-day.
Conclusion:
Compared to results in reference studies, our findings show higher rate of colonisation where as the percent occurrence is lower. Our results correspond to findings published in larger studies.
Keywords: central venous catheters; CRBSI; infection; prevention; chlorhexidine; intensive care
Received: July 15, 2008; Accepted: March 11, 2009; Published: June 1, 2009 Show citation
References
- Veenstra, D. et al. Cost-effectiveness of antiseptic-impregnated central venous catheters for prevention of catheter related blood stream infections. JAMA, 1999, 282, p. 554-560.
Go to original source...
Go to PubMed...
- Maki, D. G., Weise, C. E., Sarafin, H. W. A semiquantitative culture method for identifying intravenous-catheter-related infection. N. Engl. J. Med., 1977, 296, 23, p. 1305-1309.
Go to original source...
Go to PubMed...
- Sheretz, R. J., Raad, I. I., Belani, A. et al. Three-year experience with sonicated vascular catheter cultures in a clinical microbiology laboratory. J. Clin. Mikrobiol., 1990, 28, p. 76-82.
Go to original source...
Go to PubMed...
- Veenstra, D. L., Saint, S., Saha, S. et al. Efficacy of antiseptic impregnated central venous catheters in preventing catheter-related blood stream infections. A meta-analysis. JAMA, 1999, 281, p. 261-267.
Go to original source...
Go to PubMed...
- Timsit, J. F. Diagnosis and prevention of catheter-related infections. Curr. Opin. Care, 2007, 13, p. 563-571.
Go to original source...
Go to PubMed...
- Chaiyakunapruk, N., Veenstra, D. L. et al. Chlorhexidine compared with povidine-iodine solution for vascular catheter-site care: A meta-analysis. Ann. Intern. Med., 2002, 136, p. 792-801.
Go to original source...
Go to PubMed...
- Ho, M. K., Litton, E. Use of chlorhexidine-impregnated dressing to prevent vascular and epidural catheter colonization and infection: a meta-analysis. J. Antimicrob. Chemother., 2006, 58, p. 281-287.
Go to original source...
Go to PubMed...
- Byrnes, M., Coopersmith, C. Prevention of catheter related blood stream infections. Curr. Opin. Crit. Care, 2007, 13, p. 411-415.
Go to original source...
Go to PubMed...
- McGee, D. C., Gould, M. K. Preventing complications of central venous catheterization. NEMJ, 2003, 348, p. 1123-1133.
Go to original source...
Go to PubMed...
- Maki, D. G., Kluger, D. M., Crnich, Ch. The risk of bloodstream infection in adults with different intravascular devices: A systematic review of 200 published prospective studies. Mayo Clin. Proc., 2006, 81, 9, p. 1159-1171.
Go to original source...
Go to PubMed...
- Bach, A., Schmidt, H., Bötteger, B. et al. Retention of antibacterial activity and bacterial colonization of antiseptic-bonded central venous catheters. J. Antimicrob. Chemother., 1997, 37, p. 315-322.
Go to original source...
Go to PubMed...
- Maki, D. G., Stolz, S. M., Wheeler, S., Mermel, L. A. Prevention of central venous catheter-related bloodstream infection by use of an antiseptic impregnated catheter. A randomized, controlled trial. Ann. Int. Med., 1997, 127, p. 257-266.
Go to original source...
Go to PubMed...
- Rupp, M. E., Lisco, S. J., Lipsett, P. A. et al. Effect of a second-generation venous catheter impregnated with chlorhexidine and silver sulfadiazine on central catheter-related infection. A randomized, controlled trial. Ann. Intern. Med., 2005, 143, p. 570-580.
Go to original source...
Go to PubMed...
- Carrasco, M. N., Bueno, A. et al. Evaluation of a triple-lumen central venous heparin-coated catheter versus a catheter coated with chlorhexidine and silver sulfadiazine in critically ill patients. Int. Care Med., 2004, 30, p. 633-638.
Go to original source...
Go to PubMed...